ARRI 535B Instruction Manual Page 16

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 15
..
J
5.
Camera
Body
Mirror
Shutter
The
mirror
shutter can be adiusted mechanically while
the
camera
is
disconnected.
The
open sector can be
adjusted continuously from
180°
to
11
0
Additionally
the
mirror shutter can be locked within
the
range
of
180
0
to 1
SO
in 15°-steps, as well
as
at
172,8°
and
144°.
Setting
the
Mirror
Shutter Angle
&
Before setting the mirror shutter remove the
I
camera
from the
power
supplyl Remove the
lens
or
the lens cavity cap from
the
lens
mount receptacle.
By turning the knurled knob
on
the
movement,
position the
mirror
shutter
so
that
the
open sector
adjusting
device
and
the
locking device are
easily accessible.
With
a 2
mm
Allen key turn the locking device
towards
the
"LOOSE"
position until
it
stops.
Turn the open sector adjusting device with the
same Allen key until the desired open sector angle
is
reached.
Turn the
locking
device towards
the
"LOCK" position
until this locks
in
place.
The
adjusting device
may
possibly have
to
be turned slightly back and
forth.
Filming
with
HMI
Light
When
lighting scenes
with
HMI/CID·discharge lamps,
pay
attention to the pulsing light intensity which
is
dependent
on the supply frequency.
The
camera frame
rate, the supply frequency
of
the
lighting and the
angle
of
the
mirror
shutter must all relate
to
each other
in
order
to
achieve
constant lighting.
As
the
camera frame
rate
and
the supply frequency of
the
lighting are
normally
given, compensation
must
be
carried out
through the
angle
of
the mirror shutter.
In
the
following
table the mirror shutter angle
to
be
set
can be seen.
Supply
frequency
50
Hz
60
Hz
Frame rate
25 fps
24
fps
24
fps
Open
sector
180°
172,8°
144°
"1
......
,'!
I
"€1
.0
.i
IGj
I
!
O' i
I.i
Ei
81
I
j
I
I
I,'
2S
Page view 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 62 63