ARRI 535B Instruction Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 63
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
20
A buffer
battery
in the
magazine
enables saving and
storing the values even
if
the
magazine
is
detached.
Setting
Film
Quantity
Note:
Film
quantity
can
also be
set
while
the
magazine
is
detached
from the
camera.
If
the
magazine
is
attached, the
camera
must be
in
the
Standby position
when
setting the values.
Each SET-key stands for a position
in
the
magazine
display
.
In
order
for example
to
change the "tens"
The
follov.ring v.rork
can
be
carried
out
in
daylight.
Lay the
magazine
on the feed side (electronic film
stock
indicator facing
up).
Press
the button
and
flip up
the
locking
grip
Turn the locking
grip
counter-clockwise until it stops
and
remove the
magazine
cover
Slide the
head
of
the film into the
lower
magazine
throat assembly
opening
, until it emerges inside
the take-up compartment.
Note:
The length
of
the
loop
is
at this stage
unimportant.
It
is
set
once
the
magazine
has been
attached to the
camera.
Place the
head
of
the film in the
expandable
film
core,
clamp
it in
place
and
wind
the film roll
clockwise
approximately
one turn.
Ensure that the film
is
running
at
a right angle to the
take-up shaft.
Otherwise
the film roll can rub
against
the
magazine
cover
and
cause noise.
Magazine
Display
The
magazine
display
indicates
in
mode 1
(counter) the
remaining
amount
of
unexposed film stock
in the
magazine.
Note:
This
indicator
only
serves
as
a counter, i.e. the
indicated
value
is
calculated
based on the
set
quantity
of
film
and
is
therefore
only
as
accurate
as
the given
setting.
When
running the camera
backwards
the
counter runs
backwards.
In
mode 2 (Time
Code
Sensitivity) the film sensitivity
value for the
correct
time
code
recording can be
set
and
read.
Replace the
magazine
cover and lock.
After
loading
the magazine it
is
essential
to
set
the
magazine
display.
The
set
values are
LG.
automatically
read
by
the camera when
rhe
magazine
is
attached.
I
Lower
magazine
throat assembly opening
indicator,
the second SET-key from the left
must
be
pressed.
By
simultaneous depressing
of
the
left and right
SET-
keys the
maximum
film length for the magazine
in
use
is
set,
e.g.
on a
120
m
magazine"
120",
or ,.,393"
if
the unit
of
measurement
is
set
at feet.
The
unit
of
measurement - meters
or
feet -
is
automatically
set
when
the
magazine
is
attached
to the camera.
If,
for
example, the
camera
display
is
set
to
"feet",
the
magazine
will
also
count
in
feet when attached
to
the
camera.